5–74

Programming Parameters

Publication 1397-5.0 — June, 2001

MASKS

[Logic Mask] — P.207

This parameter determines which adapters
can control the drive. If the bit for an adapter
is set to “0”, the adapter will have no control
functions except for stop. In addition, the
adapter can be removed from the drive while
power is applied without causing a serial
fault.

Display/Drive Units:

Numeric/Text

Parameter Range:

Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6

Parameter Type:

Tunable

Group:

Masks or through Control Logic

Minimum Value:

0000000000000000

Factory Default:

0000000001111111

Maximum Value:

0000000001111111

[Local Mask] — P.208

This parameter controls which adapters are
allowed to take exclusive control of drive logic
commands (except stop). Exclusive “Local
Control” can only be taken while the drive is
stopped.

Display/Drive Units:

Numeric/Text

Parameter Range:

Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6

Parameter Type:

Read & Write

Group:

Masks

Minimum Value:

0000000000000000

Factory Default:

0000000001111111

Maximum Value:

0000000001111111