5–8
Programming Parameters
Publication 1397-5.0 — June, 2001
PARM
NAME
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
ADV SETUP 1
ADV SETUP 2
ADV SETUP 3
ADV SETUP 4
ADV SETUP 5
MOP Accel Time
MOP Decel Time
MOP Reset Enable
Preset Speed 1
Preset Speed 2
Preset Speed 3
Ref 1 Source
Ref 2 Source
Jog Acc/Dec Time
Jog Reference
Jog Off Dly Time
REF SETUP 2
REF SETUP 3
REF SETUP 4
REF SETUP 5
Min Speed Bypass
Ref Ramp Bypass
Current Compound
Inertia Comp Src
Monitor 1 Delay
Monitor 1 Source
Monitor 1 Level
Monitor 2 Delay
Monitor 2 Source
Monitor 2 Level
Normal Inertia
Reverse Disable
S-Curve Rounding
AutoTune Bridge
AutoTune Fld Rng
AutoTune Stabilty
Stop Mode Type
Stop Speed Level
Trim Mode Type
UNITS
(Hidden)
(Hidden)
(Hidden)
(Hidden)
(Hidden)
Seconds
Seconds
RPM/%FLA
RPM/%FLA
RPM/%FLA
Enum
Enum
Seconds
RPM
Seconds
(Hidden)
(Hidden)
(Hidden)
(Hidden)
Numeric
Numeric
%
Enum
Seconds
Selection
%
Seconds
Selection
%
Seconds
%
Selection
Selectable
RPM
Selectable
MIN
MAX
DEFAULT
FUNCTION
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Reference Set
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
Feature Select
TYPE
Tunable
Tunable
Tunable
Tunable
Tunable
Tunable
Tunable
Tunable
Tunable
Tunable
Configurable
Tunable
Tunable
Tunable
Tunable
Tunable
Configurable
Tunable
Tunable
Tunable
Tunable
Tunable
Configurable
Tunable
Tunable
Tunable
Tunable
Tunable
Tunable
Tunable
FUTURE
FUTURE
FUTURE
FUTURE
FUTURE
1.0
1.0
0
Min Pro Spd
Min Pro Spd
Min Pro Spd
0
0
0.10
0
0
FUTURE
FUTURE
FUTURE
FUTURE
0 (Off)
0 (Off)
–50
0
0
0
1.0%
0
0
0.1
0.05
Off
0%
0
0.90
10
0 (Ramp)
0
0 (No Trim)
USE
USE
USE
USE
USE
300
300
1
Max Pro Spd
Max Pro Spd
Max Pro Spd
14
14
300
Max Pro Spd
10
USE
USE
USE
USE
1 (On)
1 (On)
50
10
300
4
100%
30.0
4
100
65.20
1 (On)
50%
1
5.00
100
2 (Coast/DB)
Max Spd
2 (Proportion)
0.1
0.1
0
250
250
250
0
1
3.0
250
1
0 (Off)
0 (Off)
0
0
1.0
1
10%
1.0
3
10
1.00
0 (Off)
0%
0 (Forward)
1.00
25
2
50
0 (No Trim)