Within the 1397 Drive, the I/O image table resembles the following:
Logic Command
Logic Status
(parameter 190)
Bit 0
Stop
Bit 0
Ready
Bit 1
Run
Bit 1
Running
Bit 2
Jog
Bit 2
Command Dir
Bit 3
Clear Fault
Bit 3
Rotating Dir
Bit 4
Forward
Bit 4
Accelerating
Bit 5
Reverse
Bit 5
Decelerating
Bit 6
Local
Bit 6
Warning
Bit 7
MOP Increment
Bit 7
Faulted
Bit 8
N A
Bit 8
At Set Speed
Bit 9
N A
Bit 9
Local ID
Bit 10 N A
Bit 10 Local ID
Bit 11 N A
Bit 11 Local ID
Bit 12 Ref Select
Bit 12 Ref ID
Bit 13 Ref Select
Bit 13 Ref ID
Bit 14 Ref Select
Bit 14 Ref ID
Bit 15 MOP Decrement
Bit 15 Ref ID
1397
Controller
Logic Evaluation Block
Logic Status (p. 190)
Reference
Data In A1 (p. 226)
Data In A2 (p. 227)
Data In B1 (p. 228)
Data In B2 (p. 229)
Data In C1 (p. 230)
Data In C2 (p. 231)
Data In D1 (p. 232)
Data In D2 (p. 233)
Logic Status (p. 190)
Feedback
Spd Loop Fdbk (p. 22)
Data Out A1 (p. 234)
Data Out A2 (p. 235)
Data Out B1 (p. 236)
Data Out B2 (p. 237)
Data Out C1 (p. 238)
Data Out C2 (p. 239)
Data Out D1 (p. 240)
Data Out D2 (p. 241)
000 – No Command
001 – Ref 1 (Selectable)
010 – Ref 2 (Selectable)
011 – Ref 3 (Preset 1)
100 – Ref 4 (Preset 2)
101 – Ref 5 (Preset 3)
110 – N/A
111 – N/A