Programming and Parameters

Advanced Program Group

(continued)

A140 [Stp Logic 0]
A141 [Stp Logic 1]
A142 [Stp Logic 2]
A143 [Stp Logic 3]
A144 [Stp Logic 4]
A145 [Stp Logic 5]
A146 [Stp Logic 6]
A147 [Stp Logic 7]

Related Parameter(s):

P038

,

P039

,

P040

,

A051

-

A054

,

A055

,

A058

,

A061

,

A067

,

A068

,

A070

-

A077

,

A150

-

A157

,

E248

Values

Default:

00F1

Min/Max:

0001/FAFF

Display:

4 Digits

For detailed information on applying Step Logic and Position StepLogic refer to

Appendix E

and

Appendix F

.

Parameters A140-A147 are only active if

P038

[Speed Reference] is set to 6 “Stp Logic” or 9

“Positioning”.
These parameters can be used to create a custom profile of frequency commands. Each “step” can
be based on time, status of a Logic input or a combination of time and the status of a Logic input.
Digits 0-3 for each [Stp Logic x] parameter must be programmed according to the desired profile.
A Logic input is established by setting a digital input, parameters

A051

-

A054

[Digital Inx Sel], to 23

“Logic In1” and/or 24 “Logic In2” or by using Bits 6 and 7 of

E248

[Enh Control Word].

A time interval between steps can be programmed using parameters

A150

-

A157

[Stp Logic Time x].

See the table below for related parameters.
The speed for any step is programmed using parameters

A070

-

A077

[Preset Freq x].

The position for any step is programmed using parameters

E230

-

E245

[Step Units x].

Stop drive before changing this parameter.

Step

StepLogic Parameter

Related Preset Frequency Parameter

(Can be activated independent of

StepLogic Parameters)

Related StepLogic Time Parameter

(Active when A140-A147 Digit 0 or 1

are set to 1, b, C, d or E)

0

A140 [Stp Logic 0]

A070 [Preset Freq 0]

A150 [Stp Logic Time 0]

1

A141 [Stp Logic 1]

A071 [Preset Freq 1]

A151 [Stp Logic Time 1]

2

A142 [Stp Logic 2]

A072 [Preset Freq 2]

A152 [Stp Logic Time 2]

3

A143 [Stp Logic 3]

A073 [Preset Freq 3]

A153 [Stp Logic Time 3]

4

A144 [Stp Logic 4]

A074 [Preset Freq 4]

A154 [Stp Logic Time 4]

5

A145 [Stp Logic 5]

A075 [Preset Freq 5]

A155 [Stp Logic Time 5]

6

A146 [Stp Logic 6]

A076 [Preset Freq 6]

A156 [Stp Logic Time 6]

7

A147 [Stp Logic 7]

A077 [Preset Freq 7]

A157 [Stp Logic Time 7]

Step

StepLogic Position Parameters

0

E230 [Step Units 0] & E231 [Step Units F 0]

1

E232 [Step Units 1] & E233 [Step Units F 1]

2

E234 [Step Units 2] & E235 [Step Units F 2]

3

E236 [Step Units 3] & E237 [Step Units F 3]

4

E238 [Step Units 4] & E239 [Step Units F 4]

5

E240 [Step Units 5] & E241 [Step Units F 5]

6

E242 [Step Units 6] & E243 [Step Units F 6]

7

E244 [Step Units 7] & E245 [Step Units F 7]