beautypg.com

Supplemental drive information a-5 – Rockwell Automation 22D PowerFlex 40P User Manual, FRN 3 User Manual

Page 129

background image

Supplemental Drive Information

A-5

Table A.C PowerFlex 40P Estimated Watts Loss (Rated Load, Speed & PWM)

Control Outputs Relay:

Quantity:

(1) Programmable Form C

Specification

Resistive Rating:
Inductive Rating:

3.0A at 30V DC, 3.0A at 125V, 3.0A at 240V AC
0.5A at 30V DC, 0.5A at 125V, 0.5A at 240V AC

Opto:

Quantity:

(2) Programmable

Specification:

30V DC, 50mA Non-inductive

Analog:

Quantity:

(1) Non-Isolated 0-10V or 4-20mA

Specification

Resolution:
0 to 10V DC Analog:
4-20mA Analog:

10-bit
1k ohm minimum
525 ohm maximum

Category

Specification

Voltage

kW (HP)

External Watts

Internal Watts

Total Watts Loss

200–240V

0.4 (0.5)
0.75 (1.0)
1.1 (2.0)
2.2 (3.0)
3.7 (5.0)
5.5 (7.5)
7.5 (10)

22
40
63
100
150
200
265

18
20
22
25
30
35
40

40
60
85
125
180
235
305

380–480V

0.4 (0.5)
0.75 (1.0)
1.1 (2.0)
2.2 (3.0)
3.7 (5.0)
5.5 (7.5)
7.5 (10)
11 (15)

17
30
48
75
135
140
175
260

18
20
22
25
25
35
35
40

35
50
70
100
160
175
210
300

460–600V

0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
4.0 (5.0)
5.5 (7.5)
7.5 (10)
11 (15)

30
48
75
135
140
175
260

20
22
25
25
35
35
40

50
70
100
160
175
210
300