Programming and Parameters

3-57

Enhanced Program Group

(continued)

E224 [Find Home Dir]

Stop drive before changing this parameter.

Sets the direction the drive commands when “Find Home” is issued. For additional information refer to

Appendix F

.

Options

0 “Forward” (Default)

1 “Reverse”

E225 [Encoder Pos Tol]

Sets the “At Position” and the “At Home” tolerance around the encoder count. The value is added to
and subtracted from the target encoder unit value to create the tolerance range. For additional
information refer to

Appendix F

.

Values

Default:

100

Min/Max:

1/50000

Display:

1

E226 [Counts Per Unit]

Related Parameter(s):

E230

-

E245

Sets the number of encoder counts equal to one user-defined unit. For additional information refer to

Appendix F

.

Values

Default:

4096

Min/Max:

1/32000

Display:

1