E245, Enhanced program group, Continued) – Rockwell Automation 22D PowerFlex 40P User Manual, FRN 3 User Manual
Page 104: 58 programming and parameters
![background image](/manuals/577059/104/background.png)
3-58
Programming and Parameters
Enhanced Program Group
(continued)
E230 [Step Units 0]
E232 [Step Units 1]
E234 [Step Units 2]
E236 [Step Units 3]
E238 [Step Units 4]
E240 [Step Units 5]
E242 [Step Units 6]
E244 [Step Units 7]
32 bit parameter.
Sets the position in whole number user-defined units the drive must reach at each step. For additional
information refer to
.
Values
Default:
0
Min/Max:
0/64000
Display:
1
32
Input State
of Digital In 1
(I/O Terminal 05
when A051 = 4)
Input State
of Digital In 2
(I/O Terminal 06
when A052 = 4)
Input State
of Digital In 3
(I/O Terminal 07
when A053 = 4)
Position
Source
Freq
Source
Accel / Decel Parameter Used
(2)
0
0
0
E230
A070
[Accel Time 1] / [Decel Time 1]
1
0
0
E232
A071
[Accel Time 1] / [Decel Time 1]
0
1
0
E234
A072
[Accel Time 2] / [Decel Time 2]
1
1
0
E236
A073
[Accel Time 2] / [Decel Time 2]
0
0
1
E238
A074
[Accel Time 1] / [Decel Time 1]
1
0
1
E240
A075
[Accel Time 1] / [Decel Time 1]
0
1
1
E242
A076
[Accel Time 2] / [Decel Time 2]
1
1
1
E244
A077
[Accel Time 2] / [Decel Time 2]
(2)
When a Digital Input is set to “Accel 2 & Decel 2”, and the input is active, that input overrides the settings in this
table.
E231 [Step Units F 0]
E233 [Step Units F 1]
E235 [Step Units F 2]
E237 [Step Units F 3]
E239 [Step Units F 4]
E241 [Step Units F 5]
E243 [Step Units F 6]
E245 [Step Units F 7]
32 bit parameter.
Sets the position in fractional user-defined units the drive must reach at each step. For additional
information refer to
.
Values
Default:
0.00
Min/Max:
0.00/0.99
Display:
0.01
32