E220 [Ki Speed Loop]

Sets the I-Gain used in the PI calculation of the speed loop.

Values

Default:

2.0

Min/Max:

0.0/400.0

Display:

0.1

E221 [Kp Speed Loop]

Sets the P-Gain used in the PI calculation of the speed loop.

Values

Default:

0.5

Min/Max:

0.0/200.0

Display:

0.1

E222 [Positioning Mode]

Stop drive before changing this parameter.

Defines the positioning transition mode used for the position steps. For additional information refer to

Appendix F

.

Values

Default:

0

Min/Max:

0/4

Display:

1

E222 Option

Transition Mode

Description

0
1
2
3
4

Time Steps
Preset Input
Step Logic
Preset StpL
StpLogic-Lst

Steps based on time.
Preset inputs directly command a given step.
Use Step Logic commands. Always start from Step 0.
Use Preset inputs to determine starting step then Step Logic commands.
Use Step Logic commands from last StepLogic step at last drive stop.

E223 [Find Home Freq]

Sets the maximum frequency the drive uses when “Find Home” is issued. For additional information
refer to

Appendix F

.

Values

Default:

10.0 Hz

Min/Max:

0.1/500.0 Hz

Display: