beautypg.com

E216, Enhanced program group, Continued) – Rockwell Automation 22D PowerFlex 40P User Manual, FRN 3 User Manual

Page 101: E216 [motor fdbk type, E217 [motor np poles, E218 [encoder ppr, E219 [pulse in scale

background image

Programming and Parameters

3-55

Enhanced Program Group

(continued)

E216 [Motor Fdbk Type]

Stop drive before changing this parameter.

Selects the encoder type. For additional information refer to

Appendix F

.

Values

Default:

0

Min/Max:

0/5

Display:

1

E216 Option

Encoder

0
1
2
3
4
5

None
Pulse Train
Single Chan
Single Check
Quadrature
Quad Check

!

ATTENTION:

The loss of analog input, encoder or other feedback may cause

unintended speed or motion. Take appropriate precautions to guard against possible
unintended speed or motion.

E217 [Motor NP Poles]

Defines the number of poles in the motor.

Values

Default:

4

Min/Max:

2/40

Display:

1

E218 [Encoder PPR]

Specifies the encoder pulses per revolution when an encoder is used. For additional information refer
to

Appendix F

.

Values

Default:

1024

Min/Max:

1/20000

Display:

1

E219 [Pulse In Scale]

Sets the scale factor/gain for the Pulse Input when E216 [Motor Fdbk Type] is set to 1 “Pulse Train”.
For additional information refer to

Appendix F

.

Values

Default:

64

Min/Max:

1/20000

Display:

1

Input Pulse Rate

Desired Command

Speed Command

=