Presets - Times
The timing information stored in a Preset, is the FCB times for device parameters. Other timing when
used in a Sequence, such as channel times, in/delay/out times are stored in the Sequence Step. (See
Device Times - Individual or FCB
)
• The default setting for FCB times is 100% of the main In time
• The default setting for FCB delay times is 0 seconds. If you set FCB delay times in %, then
that setting refers to main In time.
These times are executed when played back from a Sequence or from a Master Playback.
Hold SETUP & press ATTRIB to open the Time settings for Parameters.
You can set them in % or as absolute times in seconds. You can select what to default to in these
Settings. Hold C/Alt and press MODIFY to set the opposite of what is currently selected.