31

Starting a Local

Management

Session

To start a local management session, perform the following procedure:

1. Connect one end of the straight-through RS232 management cable

with a DB-9 connector to the RS232 Terminal Port on the switch. (The
management cable is included with the switch.)

Figure 1 Connecting a Terminal or PC to the RS232 Terminal Port

2. Connect the other end of the cable to an RS-232 port on a terminal or

PC with a terminal emulator program.

3. Configure the terminal or terminal emulator program as follows:

❑ Baud rate: 1200 bps to 115200 bps (default 9600; see Note below)

❑ Data bits: 8

❑ Parity: None

❑ Stop bits: 1

❑ Flow control: None

DE