Displaying switch statistics, Figure 62: display module statistics window – Allied Telesis AT-S39 User Manual
Page 218
Section II: Local and Telnet Management
218
Displaying Switch Statistics
To display Ethernet statistics for the entire switch, perform the following
procedure:
1. From the Main Menu, type 7 to select Ethernet Statistics.
2. From the Ethernet Statistics menu, type 2 to select Display Module
Statistics.
The statistics for the entire switch are displayed in the Display
Module Statistics window, shown in Figure 62.
Figure 62 Display Module Statistics Window
The information in this window is for viewing purposes only. The
statistics are defined below:
Total Count
Number of valid packets received and transmitted by the switch.
Transmit Packets
Number of packets transmitted from the switch.
Received Packets
Number of packets received by the switch.
Received Overflow
Number of times the capacity of the port buffers have been
exceeded.
Allied Telesyn Ethernet Switch AT-8024 - AT-S39
Sales Switch
Login Privilege: Manager
Display Module Statistics
Ethernet statistics for this module
TOTAL_COUNT ................. 0
TX_COUNT .................... 0
RX_COUNT .................... 0
RX_BRDCAST .................. 0
RX_MLTCAST .................. 0
RX_UNICAST .................. 0
RX_OVERFLOW ................. 0
CRC_ERROR ................... 0
UNDERSIZE ................... 0
FRAGMENT .................... 0
PORT_IN_DISCARDS ............ 0
U - Update Display
C - Clear Module Statistics
R - Return to Previous Menu
Enter your selection?