Displaying Switch Statistics

To display Ethernet statistics for the entire switch, perform the following
procedure:

1. From the Main Menu, type 7 to select Ethernet Statistics.

2. From the Ethernet Statistics menu, type 2 to select Display Module

Statistics.

The statistics for the entire switch are displayed in the Display
Module Statistics window, shown in Figure 62.

Figure 62 Display Module Statistics Window

The information in this window is for viewing purposes only. The
statistics are defined below:

Total Count
Number of valid packets received and transmitted by the switch.

Transmit Packets
Number of packets transmitted from the switch.

Received Packets
Number of packets received by the switch.

Received Overflow
Number of times the capacity of the port buffers have been
exceeded.

Allied Telesyn Ethernet Switch AT-8024 - AT-S39

Sales Switch

Login Privilege: Manager

Display Module Statistics

Ethernet statistics for this module

TOTAL_COUNT ................. 0
TX_COUNT .................... 0
RX_COUNT .................... 0
RX_BRDCAST .................. 0
RX_MLTCAST .................. 0
RX_UNICAST .................. 0
RX_OVERFLOW ................. 0
CRC_ERROR ................... 0
UNDERSIZE ................... 0
FRAGMENT .................... 0
PORT_IN_DISCARDS ............ 0

U - Update Display
C - Clear Module Statistics
R - Return to Previous Menu

Enter your selection?