Partial or unsuccessful retrievals – HP NonStop G-Series User Manual
Page 376
![background image](/manuals/396922/376/background.png)
Displaying Version and System Information
Guardian User’s Guide — 425266-001
18- 8
Task 4: Interpret VPROC Output
Partial or Unsuccessful Retrievals
These diagnostic messages appear when VPROC encounters version procedure
identification problems.
Cause. Either the Guardian volume that you specified does not exist or you made a
typographical error when entering the volume-name portion of the file name or
pathname value.
Effect. If you are using VPROC interactively, VPROC prompts you for another file
name or pathname. If you are using VPROC from a TACL or an OSS shell prompt,
VPROC terminates.
Recovery. Check the volume name and enter a corrected command or value.
Cause. Either the specified file does not exist or you made a typographical error when
entering the file name or pathname value.
Effect. If you are using VPROC interactively, VPROC prompts you for another file
name or pathname. If you are using VPROC from a TACL or an OSS shell prompt,
VPROC terminates.
Recovery. Check the file name or pathname and enter a corrected command or value.
Cause. No version procedure information is stored in the specified file.
Effect. This is an informative message.
Recovery. No action is required.
Cause. No version procedure information is stored in the indicated file.
Effect. This is an informative message.
Recovery. No action is required.
Cause. Either the indicated file does not have a file code of a type that VPROC can
read, or the file contains only text data.
Effect. This is an informative message.
Recovery. No action is required.
ERROR - NO SUCH VOLUME: [ filename | pathname ]
ERROR: [ filename | pathname ] does not exist.
>>NO T9xxx PROC<<
No VPROC found in this ar-format file
Version procedure: [ filename | pathname ]: Not object file