GDS-200 & GDS-300 Series User Manual

20

BNC Panel

CH2 input

Tapped hole

CH1 input

M

W

16.5pF

300Vrms MAX.

1

1

2

CAT

300V

CH1, CH2 Inputs

Channel 1 and channel 2 BNC inputs.

Input impedance: 1MΩ
Input Capacitance: 16.5pF
Max voltage: 300V max (CAT II)

Tapped Hole

The tapped hole is used to secure the differential
probe option to the GDS-200/300. See the
differential probe manual for details.