Wayne pump and cat – Gasboy CFN III V3.6 and Later User Manual
Page 65

MDE-4739A CFN III PCI Secure Controller Software Installation/Upgrade Instructions · July 2010
Page C-3
Gilbarco D-Box, Tokheim 67/69, and Wayne EC Cabinet
Interfaces
PC Loop Application: Hardware, Software, Port, and
Communication Wiring
• There are a number of cabling options available to handle a mixture of Tokheim 67 and 98
box combinations.
• The Insight PC Loop Application can control up to 16 Insight DPTs using a Tokheim 69
box and one available serial communications port.
• 32 Insights can be controlled with two Insight PC Loop Applications, two available serial
communication ports, and two Tokheim 69 boxes.
Wayne Pump and CAT
• WaynPump and WaynCat applications require and Wayne EC Cabinet.
• This unit can control up to 12 pumps/24 fueling positions and 24 CATs.
• The WaynCat application requires the Standard Wayne CAT Interface board installed in
the Wayne EC cabinet.
• If more than 24 fueling positions are to be utilized, it is necessary to use two Wayne EC
cabinets or an Arbitration kit from Wayne.
• 24 Wayne pumps and 24 Wayne CATs would require one each of the WaynPump and
WaynCat Application kits as well as two available serial ports.