Installation
Modular Profit Point
To be PCI-compliant, the Modular Profit Point software version 3.5H or later must be installed
on a tower running Windows XPE, proceed as follows:
Notes: 1) For the procedure to reimage a tower to Windows XPE, refer to
.
2) The Modular Profit Point software version 3.5H may be loaded on a tower running
Windows NT but will not be PCI-compliant. The Modular Profit Point software
version 3.5H cannot be installed on a PC running DOS.
1
on
2
Remove the 9-pin COM 1 connector from the back of the Profit Point tower. This will stop the
CFN III from communicating to the Profit Point during the reimage and installation or upgrade
process.
COM 2 (must) and if connected COM 3 (can) remain connected.
If a serial Profit Point keyboard is used, make note of the COM port being used.
3
Reimage the tower with Windows XPE following the procedure in
, if Windows NT is currently installed.
4
Log on as the Windows XPE administrator.
5
Insert the Modular Profit CD into the CR-ROM drive and close the tray.
6
A Gasboy Installation Window will appear with the message, “You are about to install your
Profit Point software. click Install.”.
7
A warning window appears with the message, “Opening Setup.bat using.”. The “Open It”
option will be selected by default. The “Always ask before opening this type of file” check box
will have a check mark by default. Click OK or press Enter.
8
Welcome window appears. Read the information; make sure you have closed all programs.
Click Next or press Enter to continue.
9
User Information window appears. Change the user information Name and Company to one
that is appropriate for the location. Click Next or press Enter to continue.
10
Check Setup Information window appears. If the correct information has been entered, click
Next or press Enter to continue. A progress window appears showing the files being
transferred.
11
“Is the date and time shown above correct? (Y or N)”
window appears. Do not press Enter.
Perform the steps outlined in
on
12
Profit Point Installation Menu appears. Select either New Installation or Update the Profit
Point Program. Perform the steps outlined in step
.
13
Do not remove the Profit Point CD-ROM disk.