beautypg.com

Changes in cfn iii version 3.6 for pci compliance, Sign on/users/password changes, Backup password – Gasboy CFN III V3.6 and Later User Manual

Page 16: Master password, Master password procedure

background image

Before You Begin

Backing Up Data

Page 10

MDE-4739A CFN III PCI Secure Controller Software Installation/Upgrade Instructions · July 2010

Failure to complete the Floppy Disk Backup procedure will require the onsite technician to
completely reload all CFN III, network, and if installed Profit Point configuration, settings,
and data.

Note: Unless you have access to the original Windows NT OS CD image or the original

Windows NT CD and disk sets, you will not be able to go back to the original

Windows NT OS.

Changes in CFN III Version 3.6 for PCI Compliance

• The required PCI version will be Gasboy version 3.6A or later.
• All Gasboy versions of 3.4 and earlier are not PCI-compliant.

Gasboy Profit Point Software Version 3.5H or Later Required

This can only be installed on computers running Windows NT or Windows XPE OSs. DOS
Modular Profit Points are unable to load the new software. An additional Microsoft license for
Windows XPE is required for each modular Profit Point that is updated to Windows XPE,
other than the SC3 tower license.

Sign On/Users/Password Changes

The original commands of LOad SIGon, ADd SIGon, and REMove SIGon no longer exist.
Print SIGon will remain.

Note: All original User’s Sign On and Password will no longer exist or function.

Backup Password

The backup password of “GASBOY” on page 1 of “sys_par” no longer allows you to log on to
the system. The backup password is now used by the system to generate the “Master
Password”.

Master Password

Master Password is the new secure procedure to gain initial access to the CFN III after an
upgrade to a PCI-complaint version. Contact the Gasboy Help Desk to obtain a Master
Password. The Master Password is a one-time-use-only password. If the Master Password is
allowed to time out before adding a new level 10 user with Admpass, a new Master Password
is required to be generated to gain access.

Master Password Procedure

The entry of: “97, (backup password loaded, Page 1 Sys_par)” at the “Sign On” prompt will
generate a 2-part code (CPU ID and PASSKEY). Contact Gasboy Help Desk at

1-800-444-5529. They will use the 2-part code to generate a “Master Password”. The entry of
“98,(Master Password generated)” will gain temporary access to the CFN III system.