beautypg.com

EXFO AXS-200/850 Ethernet Test Set User Manual

Page 73

background image

RFC 2544

Ethernet Test Set

63

Stream Configuration

³

Destination IP Address: Enter the destination IP address.

The default setting for IPv4 is 10.10.0.0, or is set automatically to the IP
address of the target module that is looped up from Remote Loopback
mode.

The default setting for IPv6 is
2001:0000:0000:0000:0000:0000:0000:0000
, or is set automatically to
the IP address of the target module that is looped up from Remote
Loopback
mode.

The accepted range for IPv4 is 0.0.0.0 to 255.255.255.255. The default
value is 0.0.0.0.

The IPv6 Address can either be the Link-Local IPv6 Address or the
Global IPv6 Address.

The acceptable range for IPv6 is from
000:0000:0000:0000:0000:0000:0000:0001 to
FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF.

When the IP Address field is selected for editing, the Latest IP’s
button appears on the bottom of the screen. Press the corresponding
function key to display the list of previously configured IP addresses.
Select the desired IP address from the list, if any.

³

Quick Ping: Select the Quick Ping button to test if the destination
IP address can be reached. A message will be returned to indicate
if the ping attempt was Successful or Failed.

Note: When a remote module is looped up, the Destination IP Address is not

configurable (read only). When a remote module is looped down, the
Destination IP Address reverts to the previously configured value.

³

TTL for IPv4 and Hop Limit (TTL) for IPv6

Enter the Time to Live (TTL) value. The accepted range is from
0 to 255 with a default of 128.