beautypg.com

EXFO AXS-200/850 Ethernet Test Set User Manual

Page 136

background image

Traffic Generation & Monitoring

126

AXS-200/850

Global Configuration

³

Frame Size (Bytes): Set the frame size for Ethernet and
Ethernet/IPv4/UDP or Ethernet/IPv6/UDP. The default value will be
equal to the minimum frame size or to 64 bytes if the minimum frame
size is under 64 bytes. The minimum frame size varies with the framing
selection, number of VLAN layers configured, and proprietary
information insertion for jitter, latency and sequence tracking.

The following table displays the minimum and maximum frame size:

³

Payload: Payload is available only when Jitter is disabled. Set the
payload of the frames in hexadecimal format. The accepted range is
from 00 to FF. The default value is CC.

Frame

Type

Minimum Frame Size (Bytes)

Maximum

Frame Size

(Bytes)

Jitter

Yes

No

Latency

Yes

No

Yes

No

Sequence

Tracking

Yes

No

Yes

No

Yes

No

Yes

No

Ethernet

No VLAN

98

84

84

70

80

66

66

48

9600

One VLAN 102

88

88

74

84

70

70

48

9600

Two VLAN 106

92

92

78

88

74

74

48

9600

Ethernet/
IPv4/UDP

No VLAN

98

84

84

70

80

66

66

52

9600

One VLAN 102

88

88

74

84

70

70

56

9600

Two VLAN 106

92

92

78

88

74

74

60

9600

Ethernet/
IPv6/UDP

No VLAN

118

104

104

90

100

86

86

72

9600

One VLAN 122

108

108

94

104

90

90

76

9600

Two VLAN 126

112

112

98

108

94

94

80

9600