EXFO AXS-200/850 Ethernet Test Set User Manual
Page 112

BERT
102
AXS-200/850
Stream Configuration
If not resolved after 3 seconds, the MAC value becomes “--” and the
stream is disabled. In the next status field, a Not Resolved status will
appear. The status field also displays “--” when the Resolve MAC
Address is disabled, and other status includes Failed, Not Resolved,
and Resolved. The default status is “--”.
³
Destination IP Address: Enter the Destination IP Address.
The default setting for IPv4 is 10.10.0.0 or is set automatically to the IP
address of the target module from Remote Loopback mode. The
default setting for IPv6 is 2001:0000:0000:0000:0000:0000:0000:0000.
It can also be set automatically to the IP address of the target module
from Remote Loopback mode. It should be a valid Link-Local IPv6
Address (LLA) or Global IPv6 Address (GUA) address.
The accepted range for IPv4 is 0.0.0.0 to 255.255.255.255. The default
value is 0.0.0.0. The IPv6 Address can either be the Link-Local IPv6
Address or the Global IPv6 Address. The acceptable range for IPv6 is
from 000:0000:0000:0000:0000:0000:0000:0001 to
FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF.
When the IP Address field is selected for editing, the Latest IP’s
button appears on the bottom of the screen. Press the corresponding
function key to display the list of previously configured IP addresses.
Select the desired IP address from the list, if any.
³
Quick Ping: Select the Quick Ping button to test if the destination
IP address can be reached. A message will be returned to indicate
if the ping attempt was Successful or Failed.
Note: When a remote module is looped up, the Destination IP Address is not
configurable (read only). When a remote module is looped down, the
Destination IP Address reverts to the previously configured value.
³
TTL for IPv4 and Hop Limit (TTL) for IPv6
Enter the Time to Live (TLL) value. The accepted range is from
0 to 255 with a default of 128.