Unidirectional BERT testing is performed whereby the test stream is
transmitted from the local module to a remote device in loopback, and the
test stream is received back and locally analyzed. The results are reported
at the local end.

Bidirectional BERT testing is composed of two independent tests where
traffic transmitted from one end will be analyzed at the other end. Test
synchronization between 2 units is performed on a best-effort basis. Any
alarms/errors due to incorrect synchronization can be cleared while the
test is running. The test results for each direction are reported only at the
receive end. There is no exchange of results between test units. The local
and remote modules can be either an AXS-200/850 Ethernet Test Set or
FTB-8510/8510B/8510G.

The BERT menu offers the following structure:

SubMenu

Tab

Page

Configuration Global Configuration

97

Stream Configuration

101

Results

Summary Results

105

Detailed Results

111

Service Disruption Results

112

Alarms/Errors

114

Logger

Logger

117