beautypg.com

EXFO AXS-200/850 Ethernet Test Set User Manual

Page 137

background image

Traffic Generation & Monitoring

Ethernet Test Set

127

Global Configuration

³

Throughput Pass/Fail Verdict: Select the type of Throughput
Pass/Fail Verdict
criteria. Choices are Current RX Rate, Average RX
Rate
, and Disabled. The Current RX Rate correspond to the Average
RX Rate
of the last second. The Average RX Rate corresponds to the
average rate since the beginning of the test.

³

Thresholds Min/Max: Set the Minimum and Maximum threshold
values if threshold is enabled.

When the Throughput Pass/Fail Verdict is selected as Current RX
Rate
, the Pass/Fail Verdict is declared as Fail as soon as the test-stream
current receive rate is over the maximum threshold or below the
minimum threshold.

When the Throughput Pass/Fail Verdict is selected as Average RX
Rate
, the Pass/Fail Verdict is declared as Fail as soon as the test-stream
average receive rate is over the maximum threshold or below the
minimum threshold. The Pass/Fail Verdict is evaluated every second,
the final Pass/Fail Verdict correspond to the verdict at the last second of
the test.

When the Throughput Pass/Fail Verdict is selected as Disabled, the
Pass/Fail Verdict is not displayed.

³

Restore Defaults: Press Restore Defaults to restore the default
configuration for main and background streams.