background image

BERT

116

AXS-200/850

Alarms/Errors

Errors

³

Symbol (100/1000 Mbps): A Symbol Error is declared when an
invalid code-group in the transmission code is detected.

³

FCS: The number of received frames with an invalid FCS.

³

Alignment (10/100 Mbps): Indicates the number of received
frames without an integral number of octets in length.

³

Jabber: The number of received frames larger than 1518 (no VLAN
tag), 1522 (One VLAN tag), 1526 (Two VLAN tags), or 1530 (3 VLAN
tags) bytes with an invalid FCS.

³

Runt: The number of received frames that are smaller than
64 bytes with an invalid FCS.

³

Undersize: The number of received frames smaller than 64 bytes
with a valid FCS.

The following errors are only available with Half Duplex mode (only for
electrical interface at speeds of 10 Mbps and 100 Mbps).

³

Collision: Indicates the number of collisions on the link.

³

Late Coll.: Indicates the number of collisions that have occurred
after a 64 bytes transmission.

³

Exc. Coll.: Indicates the number of frames that were sent 16 times
unsuccessfully due to consecutive collisions.

The Errors LEDs are described as follows:

Color

Meaning

Green

No error.

Red

A test is running and there is at least one error

present (Current).

Amber

There was at least 1 error reported (History).

Black

Not applicable.