background image

Configuring and Starting a Test or Tool

28

AXS-200/850

Configuring a BERT Test

Configuring a BERT Test

To configure the BERT test:
1.
Configure the interface by configuring the port, network, and VLAN

settings. Refer to Interface on page 33. Ensure that the link is up
(indicated by the platform LED) before proceeding to the next step.

2. Optionally, set a remote module in loopback. Refer to Remote

Selection on page 45.

3. Press ,

select

BERT, Configuration, and the Global tab.

4. Configure the global settings by referring to Global Configuration on

page 97.

5. Select the Stream tab.

6. Configure the stream by referring to Stream Configuration on page 101.

7. Press

to start or stop the test.