Stream Configuration

The possible values are shown as follows:

³

If DS is selected, go to the next field to
enter the hexadecimal code 00 to FF or
go to the field underneath to enter the
binary code.

Parameter

Value

Bit

Precedence

000 (Routine), 001 (Priority), 010 (Immediate),

011 (Flash), 100 (Flash Override),

101 (CRITIC/ECP), 110 (Internet Control),

111 (Network Control)
Default: 000 (Routine)

1-3

Throughput

Normal / High (0/1)
Default: Normal

4

Monetary Cost

Normal / Low (0/1)
Default: Normal

5

Delay

Normal / Low (0/1)
Default: Normal

6

Reliability

Normal / High (0/1)
Default: Normal

7

Reserved bit

0 or 1
Default: 0

8