1 selection help, Selection help, 5motor control (mctrl) – Lenze 8400 BaseLine C User Manual
Page 75

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
75
5
Motor control (MCTRL)
5.2
Selecting the control mode
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.2.1
Selection help
To ease the selection of the motor control mode, the two following tables contain recommendati-
ons and alternatives to standard applications.
[5-1]
Standard applications without speed feedback
Application
Recommended
Alternatively
Single drives
With constant load
VFCplus: V/f linear
SLVC
With extremely alternating loads
VFCplus: V/f linear
SLVC
With high starting duty
SLVC
VFCplus: V/f linear
Torque limitation
SLVC
-
With torque limitation (power control)
VFCplus: V/f linear
SLVC
Three-phase reluctance motor
VFCplus: V/f linear
-
Three-phase sliding rotor motor
VFCplus: V/f linear
-
Three-phase AC motors with permanently assigned frequen-
cy/voltage characteristic
VFCplus: V/f linear
-
Pump and fan drives with quadratic load characteristic
VFCplus: V/f quadratic
VFCplus or SLVC
Simple hoists
VFCplus: V/f linear
-
Group drives (several motors connected to controller)
Identical motors and loads
VFCplus: V/f linear
-
Different motors and/or alternating loads
VFCplus: V/f linear
-