C00868 | can output words, C00909 | speed limitation, C909/1 – Lenze 8400 BaseLine C User Manual
Page 295: C909/2, C909, Or out, C868/1, C868/2, C868/3, C868/4

10
Parameter reference
10.2
Parameter list | C00868
295
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00868
C00909
Parameter | Name:
C00868 | CAN output words
Data type: UNSIGNED_16
Index: 23707
d
= 5C9B
h
Display of the 16-bit output values of the CAN interface
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Bit0
Bit 1 Bit1
Bit 2 Bit2
Bit 3 Bit3
Bit 4 Bit4
Bit 5 Bit5
Bit 6 Bit6
Bit 7 Bit7
Bit 8 Bit8
Bit 9 Bit9
Bit 10 Bit10
Bit 11 Bit11
Bit 12 Bit12
Bit 13 Bit13
Bit 14 Bit14
Bit 15 Bit15
Subcodes
Info
C00868/1
: wOut1
C00868/2
: wOut2
C00868/3
: wOut3
C00868/4
: wOut4
C00868/5
: wOut1
C00868/6
: wOut2
C00868/7
: wOut3
C00868/8
: wOut4
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00909 | Speed limitation
Data type: INTEGER_16
Index: 23666
d
= 5C72
h
Maximum positive/negative speed for all operating modes
Setting range
(min. value | unit | max. value)
0.0
%
175.0
Subcodes
Lenze setting
Info
C00909/1
120.0 %
Max. pos. speed
C00909/2
120.0 %
Max. neg. speed
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100