4 import epm data, 5 enable/inhibit controller, 6 activate/deactivate quick stop – Lenze 8400 BaseLine C User Manual
Page 50: Import epm data, Enable/inhibit controller, Activate/deactivate quick stop, Activate/deactivate quick stop ( 50), 4device control (dctrl)
4
Device control (DCTRL)
4.1
Device commands
50
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.1.4
Import EPM data
The
= "1: On / start" device command activates the automatic import of parameters from
the memory module after the error message "PS04: Par.set incompatible".
4.1.5
Enable/Inhibit controller
= "1: On / start" device command enables the controller, provided that no other source
of a controller inhibit is active.
The
= "0: : On / start" device command enables the controller, provided that no other sour-
ce of a controller inhibit is active.
• The motor becomes torqueless and coasts down.
• When the controller is inhibited, the status output bCInhActive of the
system
block is set to TRUE.
• When the controller inhibit request is reset, the drive synchronises to the actual speed. For this
purpose,
• If the flying restart circuit is activated in
, the flying restart function parameterised in
is used for the synchronisation to the rotary or standing drive.
Tip!
• The controller can also be enabled or inhibited via the
and
toolbar icons.
•
provides a bit coded representation of all active sources/triggers of a controller in-
hibit.
4.1.6
Activate/Deactivate quick stop
= "1: On / start" device command activates the quick stop function, i.e. the motor con-
trol is separated from the setpoint selection, and within the deceleration time parameterised in
the motor is brought to a standstill (n
act
= 0).
• A pulse inhibit (CINH) is set if the "Auto-DCB" function has been activated via
.
The
= "0: Off / ready" device command deactivates the quick stop again, provided that no
other source of a quick stop is active.
Tip!
provides a bit coded representation of all active sources/triggers of a quick stop.
Parameter
Info
Lenze setting
Value Unit
Deceleration time - quick stop
2.000 s