Parameter list | C00142
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00142
C00144
Parameter | Name:
C00142 | Auto-start option
Data type: UNSIGNED_8
Index: 24433
d
= 5F71
h
Starting performance of the controller after mains connection and reset of "Trouble" or "Fault".
"Inhibit at power-on" auto-start option
Setting range
(min. hex value | max. hex value)
Lenze setting
0x00
0xFF 0x01 (decimal: 1)
Value is bit-coded: ( = bit set)
Bit 0 Inhibit at mains ON
Bit 1 Inhibit at trouble
Bit 2 Inhibit at fault
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00144 | Switching frequency reduction (temp.)
Data type: UNSIGNED_8
Index: 24431
d
= 5F6F
h
Activation of the automatic switching frequency reduction at too high temperature
Selection list
(Lenze setting printed in bold)
Info
0 Off
Automatic switching frequency reduction deactivated
1 On
Automatic switching frequency reduction activated
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1