beautypg.com

1 terminals 0, 2 terminals 2, Terminals 0 – Lenze 8400 BaseLine C User Manual

Page 140: Terminals 2, 7drive application

background image

7

Drive application

7.3

Setting parameters (short overview)

140

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.5.1

Terminals 0

7.5.2

Terminals 2

Connection

Assignment

Connection

Assignment

RFR

LA_NCtrl.bFailReset

A1U

LA_NCtrl.nMainSetValue_a

10 V ≡ 100 % reference speed (

C011

)

DI1

LA_NCtrl.bJogSpeed1

DI2

LA_NCtrl.bJogSpeed2

DI3

LA_NCtrl.bSetDCBrake

NO, COM

LA_NCtrl.bDriveFail

DI4

LA_NCtrl.bSetSpeedCcw

DO1

LA_NCtrl.bDriveReady

X101

NO

COM

GND

A1U

AR

RFR

DI1

DI2

DI3

DI4

24E

DO1

12I

X4

+

Speed setpoint

Enable controller / reset error message

Selection of fixed setpoint 1/3

Selection of fixed setpoint 2/3

Manual DC-injection braking (DCB)

Direction of rotation CCw

External supply 24 V DC

DriveFail

DriveReady

Connection

Assignment

Connection

Assignment

RFR

LA_NCtrl.bFailReset

A1U

LA_NCtrl.nMainSetValue_a

10 V ≡ 100 % reference speed (

C011

)

DI1

LA_NCtrl.bJogSpeed1

DI2

LA_NCtrl.bJogSpeed2

DI3

LA_NCtrl.bSetQuickstop

NO, COM

LA_NCtrl.bDriveFail

DI5

LA_NCtrl.bBrkRelease

DO1

LA_NCtrl.bDriveReady

X101

NO

COM

GND

A1U

AR

RFR

DI1

DI2

DI3

DI4

24E

DO1

12I

X4

+

Speed setpoint

Enable controller / reset error message

Selection of fixed setpoint 1/3

Selection of fixed setpoint 2/3

Quick stop

Direction of rotation CCw

External supply 24 V DC

DriveFail

DriveReady