1 load lenze setting, 2 loading parameter settings, Load lenze setting – Lenze 8400 BaseLine C User Manual
Page 48: Loading parameter settings, 4device control (dctrl)

4
Device control (DCTRL)
4.1
Device commands
48
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.1.1
Load Lenze setting
= "1: : On / start" device command resets the parameters to the Lenze setting which are
saved in the controller firmware.
• Can only be executed if the controller is inhibited; otherwise, the feedback
= "6: No ac-
cess - controller inhibit" will be returned.
• All parameter changes which have been carried out after the last time the parameter settings
were saved will be lost!
• This device command has an effect on the settings of the parameters of the operating system,
application and module.
How to load the Lenze setting:
1. If the controller is enabled, it must be inhibited, e.g. by executing the "Enable/Inhibit cont-
roller" device command" (
= "0: Off / ready").
2. Execute the "Load Lenze setting" device command
= "1: On / start"
The load process may take a couple of seconds. After the device command has been called
in
a dynamic status information ("Work in progress" "Off / ready") is returned.
4.1.2
Loading parameter settings
The
= "1: On / start" device command reloads all parameters from the memory module to
the controller.
• Can only be executed if the controller is inhibited; otherwise, the feedback
= "6: No ac-
cess - controller inhibit" will be returned.
• All parameter changes which have been carried out after the last time the parameter settings
were saved will be lost!
• This device command has an effect on the settings of the parameters of the operating system,
application and module.
How to reload the starting parameter settings from the memory module:
1. If the controller is enabled, it must be inhibited, e.g. by executing the "Enable/Inhibit cont-
roller" device command (
= "0: Off / ready").
2. Execute the "Load Lenze setting" device command:
= "1: On / start"
The load process may take a couple of seconds. After the device command has been called
in
2 a dynamic status information ("Work in progress" "Off / ready") is returned.
Note!
When the device is switched on, all parameters are automatically loaded from the me-
mory module to the main memory of the controller.