I-1600, I-1601, 9system bus "can on board – Lenze 8400 BaseLine C User Manual
Page 223

9
System bus "CAN on board"
9.9
Implemented CANopen objects | I-1600
223
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
I-1600
The object I-1600 serves to receive parameter data as RPDO1.
• This object relates to codes
[9-22] Data telegram assignment
IEC 61131 process data words are mapped. Only whole bytes can be mapped (1-byte/mapping ent-
ry).
Related topics:
RPDO1 | Port block "LP_CanIn1"
I-1601
The object I-1601 serves to receive parameter data as RPDO2.
• This object relates to codes
• For data telegram assignment, see object
Related topics:
RPDO2 | Port block "LP_CanIn2"
Index:
I-1600
Name:
RPDO1 mapping parameter
Subindex
Default setting
Display range (min. value | unit | max. value)
Access
Data type
0: Number of mapped application ob-
jects in PDO
0
0
8 rw
U8
1 ... 4: Application object 1 ... 4
0
0
4294967295 rw
U32
Subindex
Meaning
0
Number of mapped objects
1 ... 4
Mapping entries 1 ... 4 for RPDO1
• The 4th mapping entry is used for the statistic mapping. For this, there is no value
available.
8th byte
7th byte
6th byte
5th byte
Data 4
Data 3
Data 2
Data 1
Bit 31 ... bit 16
Bit 15 ... bit 8
Bit 7 ... bit 0
Index
Subindex
Length
Index:
I-1601
Name:
RPDO2 mapping parameter
Subindex
Default setting
Display range (min. value | unit | max. value)
Access
Data type
0: Number of mapped application ob-
jects in PDO
0
0
8 rw
U8
1 ... 4: Application object 1 ... 4
0
0
4294967295 rw
U32
Subindex
Meaning
0
Number of mapped objects
1 ... 4
Mapping entries 1 ... 4 for RPDO2
• The 4th mapping entry is used for the statistic mapping. For this, there is no value
available.