3commissioning – Lenze 8400 BaseLine C User Manual
Page 35

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
35
3
Commissioning
3.4
Commissioning with the »Engineer«
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameterise application
On the right of the Application parameters tab, the parameters of the application are arranged:
1. Select the required control mode in the Control mode (
) list field.
• The corresponding wiring diagram is displayed in a pop-up window if you click the
button
right to the list field.
• For a detailed description, see chapter entitled "
Terminal assignment of the control modes
".
2. Optional: Use process controller.
• For this purpose select the required operating mode in the L_PCTRL_1: Operating mode
(
) list field.
• For a detailed description see the function block
• The parameterisation dialog of the process controller can be accessed via the Process
controller button.
3. Optional: Use motor potentiometer.
• For this purpose, select "1: On" in the L_MPot_1: Use (
) list field.
• For a detailed description see the function block
• The parameterisation dialog of the process controller can be accessed via the Motor
potentiometer button.