C00802 | l_mpot_1: acceleration time, C00803 | l_mpot_1: deceleration time, C00804 | l_mpot_1: inactive fct – Lenze 8400 BaseLine C User Manual
Page 291: C00805 | l_mpot_1: init fct, C805, C802, C803, C804, 10 parameter reference

10
Parameter reference
10.2
Parameter list | C00802
291
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00802
C00803
C00804
C00805
Parameter | Name:
C00802 | L_MPot_1: Acceleration time
Data type: UNSIGNED_16
Index: 23773
d
= 5CDD
h
FB
: Acceleration time of the motor potentiometer function
Setting range
(min. value | unit | max. value)
Lenze setting
0.1
s
999.9 10.0 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00803 | L_MPot_1: Deceleration time
Data type: UNSIGNED_16
Index: 23772
d
= 5CDC
h
FB
: Deceleration time of the motor potentiometer function
Setting range
(min. value | unit | max. value)
Lenze setting
0.1
s
999.9 10.0 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00804 | L_MPot_1: Inactive fct.
Data type: UNSIGNED_8
Index: 23771
d
= 5CDB
h
FB
: Selection of the response when deactivating the motor potentiometer via the bInAct input
Selection list
(Lenze setting printed in bold)
Info
0 Keep value
Keep output value
1 Deceleration to 0
Deceleration via ramp to 0
2 Deceleration to lower limit
Deceleration via ramp to lower limit (
3 Without ramp to 0
Jump to 0
4 Without ramp to lower limit
Jump to lower limit (
)
5 Acceleration to upper limit
Acceleration via ramp to upper limit (
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00805 | L_MPot_1: Init fct.
Data type: UNSIGNED_8
Index: 23770
d
= 5CDA
h
FB
: Selection of the response when switching on the device
Selection list
(Lenze setting printed in bold)
0 Load last value
1 Load lower limit
2 Load 0
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1