C00159 | cause for quick stop qsp, C00165 | error information, C00166 | error information text – Lenze 8400 BaseLine C User Manual
Page 260: C165, C159, Provides, Provides a, C166/1, Is use, C165/1

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
260
10
Parameter reference
10.2
Parameter list | C00159
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00159
C00165
C00166
Parameter | Name:
C00159 | Cause for quick stop QSP
Data type: UNSIGNED_16
Index: 24416
d
= 5F60
h
Bit-coded display of the cause/source of quick stop
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Terminal
Bit 1 CANDriveControl
Bit 2 Reserved
Bit 3 SwitchOn
Bit 4 Application
Bit 5 Device command
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00165 | Error information
Data type: VISIBLE_STRING
Index: 24410
d
= 5F5A
h
Display of the error numbers divided into sectors in the case of an error
Subcodes
Info
C00165/1
Current error
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00166 | Error information text
Data type: VISIBLE_STRING
Index: 24409
d
= 5F59
h
Display of details of the currently pending error
Subcodes
Info
C00166/1
Resp. - current error
• Response of the currently pending error
C00166/2
Subj.area curr. error
• Subject area of the currently pending error
C00166/3
Mess.curr.error
• Textual message of the currently pending error
Read access Write access CINH PLC STOP No transfer COM MOT