3 l_smc_readparameter, L_smc_readparameter – Lenze PLC Designer PLC-Designer (R2-x) SoftMotion User Manual
Page 265
![background image](/manuals/566299/265/background.png)
DMS 5.2 EN 03/2011 TD17
L
265
L-force | PLC Designer - SoftMotion
The L_SMC_DriveUtil.lib library (Lenze specifications)
Function blocks for EtherCAT
12.2.3
L_SMC_ReadParameter
This block serves to read out codes of a Motion drive. The code and subindex are specified
directly at the block. The conversion to the corresponding parameter number is carried out
internally.
Inputs (VAR_INPUT)
Enable : BOOL
Activates the function.
wCodeStelle: WORD
Specification of the code that is to be read.
bySubIndex: BYTE
Specification of the subindex that is to be read.
Axis : AXIS_REF
Here the axis structure for which the code is to be read is transferred.
Outputs (VAR_OUTPUT)
Done : BOOL
TRUE indicates that the selection has been acknowledged.
Error : BOOL
TRUE indicates that an error has occurred in the function block.
ErrorID: INT
Error number
dwValue : DWORD
Value read
Error messages
The following error messages are stored:
SMC_RP_PARAM_UNKNOWN:=130
Unknown code
SMC_RP_REQUESTING_ERROR:=131
Read request was aborted, e.g. because the drive has not responded within the time
specified.