The L_SMC_DriveUtil.lib library (Lenze specifications)

L_SMC_TouchProbe

Error messages
The following error messages are stored:

Error number

Description

411

TouchProbeSelect incorrect: TP channel not available

• TouchProbeSelect > 1 for ECSxM

• TouchProbeSelect > 2 for Servo Drive 9400

412

TouchProbeMode incorrect:

• TouchProbeMode > 1 for ECSxM (Only ’Single measurement’ is supported.)

• TouchProbeMode > 2 for Servo Drive 9400

413

TouchProbeEdge incorrect: If "TouchProbeSignal = zero pulse" is selected, only the ’positive

edge’ edge evaluation is possible

• TouchProbeMode > 1 for ECSxM (Only ’Single measurement’ is supported.)

• TouchProbeMode > 2 for Servo Drive 9400

414

TouchProbeEdge incorrect: Requested edge evaluation is not available

• TouchProbeEdge > 2 for ECSxM (Only positive or negative edge possible.)

• TouchProbeEdge > 4 for Servo Drive 9400 (Type of edge evaluation is not supported.)

415

TP channel not free:

TP channel has already been activated via another block.

416

Touch probe is not possible for the currently selected process data mapping.

417

Internal error / TP channel not free:

TP channel has already been activated via another block.

418

Internal error:

Timeout during command to be executed of the drive

420

Servo Drive 9400: Incorrect PDO mapping, no touch probe data contained.

421

ECSxM: Selected channel is not supported, only channel "1" permissible

422

ECSxM: Selected mode is not supported, only "Single measurement" permissible

423

ECSxM: Selected edge evaluation is not supported, only "Triggering with positive edge"

permissible