The modular system, 2/4×counter – Lenze EPM−T9XX Modular system User Manual
Page 99

2/4×counter
The modular system
4.21
L
4.21−3
EDSPM−TXXX−9.0−11/2009
Mode of
Compare
Load
Auto
Reload
OUT1
OUT0
IN6
IN5
IN4
IN3
IN2
IN1
Function
[h]
Compare
Load
Auto
Reload
OUT1
OUT0
IN6
IN5
IN4
IN3
IN2
IN1
Function
[dec]
0C
h
12
2 × 32−bit counters
(counting direction up)
RES
CLK
GATE
RES
CLK
GATE
·
·
–
ü
0D
h
13
2 × 32−bit counters
(counting direction down)
RES
CLK
GATE
RES
CLK
GATE
·
·
–
ü
0E
h
14
2 × 32−bit counters
(counting direction up)
RES
CLK
GATE
RES
CLK
GATE
·
·
ь
ь
0F
h
15
2 × 32−bit counters
(counting direction down)
RES
CLK
GATE
RES
CLK
GATE
·
·
ь
ь
1 counter
0/1
10
h
16
Frequency measuring
RES
CLK
START
STOP
–
–
·
·
–
ü
11
h
17
Measuring the period
RES
CLK
START
STOP
–
–
·
·
–
ü
12
h
18
Frequency measuring
(Counter output on/off)
RES
CLK
START
STOP
–
–
·
·
–
ü
13
h
19
Measuring the period
(Counter output on/off)
RES
CLK
START
STOP
–
–
·
·
–
ü
2 counters
0
1
06
h
6
Measuring the pulse width
(f
ref
50 kHz, counting direction is
selectable)
RES
PULSE
DIR
RES
PULSE
DIR
–
–
–
–
14
h
20
Measuring the pulse width
(f
ref
programmable, counting
direction is selectable)
RES
PULSE
DIR
RES
PULSE
DIR
–
–
–
–
15
h
21
Measuring the pulse width
(f
ref
programmable, counting
direction: Upwards)
RES
PULSE
GATE
RES
PULSE
GATE
–
–
–
–
16
h
22
Measuring the pulse width
(f
ref
programmable, counting
direction: Downwards)
RES
PULSE
GATE
RES
PULSE
GATE
–
–
–
–
2 counters
0
1
17
h
23
2 × 32−bit counters
(counting direction up, "Set"
function)
RES
CLK
GATE
RES
CLK
GATE
–
–
–
ü
18
h
24
2 × 32−bit counters
(counting direction down, "Set"
function)
RES
CLK
GATE
RES
CLK
GATE
–
–
–
ü
19
h
25
2 × 32−bit counters
(counting direction up, "Reset"
function)
RES
CLK
GATE
RES
CLK
GATE
–
–
–
ü
1A
h
26
2 × 32−bit counters
(counting direction down, "Reset"
function)
RES
CLK
GATE
RES
CLK
GATE
–
–
–
ь