The modular system, 4×relay – Lenze EPM−T9XX Modular system User Manual
Page 63

4×relay
The modular system
4.12
L
4.12−3
EDSPM−TXXX−9.0−11/2009
Maximum relay contact switching capacity
Relay contact life
20 30
50
100
200 300
U [V]
0.2
0.5
2
3
4
5
1
0.3
0.4
I [A]
100
50
30
20
10
0.5
1
2
3 4 5
10
100
n
epm−t018
epm−t019
Fig. 4.12−3
Diagrams for the module 4×relay
I
Contact current
n
Number of switching cycles × 10
4
U
Contact voltage
Service life at AC 125 V
Switching capacity at AC voltage
Service life at DC 30 V
Switching capacity at DC voltage
Service life at AC 230 V
Type
4×relay
Voltage supply
DC 5 V / 150 mA (via backplane bus)
Connectable cable cross−section
£ 2.5 mm
2
(
³ AWG 14)
Relay outputs
Number
4
Max. contact voltage
AC 230 V
DC 30 V
Max. contact current
5A
Max. relay switching frequency
100 Hz
Communication
Output data
1 byte (bit 0 ... bit 3)
Dimensions
Width
25.4 mm
Height
76.0 mm
Depth
76.0 mm
Weight
80 g
Order designation
EPM−T222
Technical data