Parameterising 2/4xcounter module
2 x 32 bit counter (mode 0)
Parameter setting via PROFIBUS−DP
13.2
13.2.3
L
13.2−5
EDSPM−TXXX−9.0−11/2009
13.2.3
2 x 32 bit counter (mode 0)
epm−t064
Fig. 13.2−2
Terminal assignment of the 2/4xcounter in the mode 0
The mode 0 offers two 32−bit counters which can be assigned with a starting value.
Each LOW−HIGH edge at input IN2 / IN5 (CLK) increments and/or decrements the
counter by 1, respectively.
The counting direction is determined via the signal level at input IN3 / IN6 (DIR):
Upcounter: LOW level
Downcounter: HIGH level
During the counting process, a LOW level must be applied to input IN1 / IN4 (RES).
A HIGH level deletes the counter.
When the counter reaches zero, the output OUT0 / OUT1 is set to HIGH level for
at least 100 ms, even if the counter continues to count. When the counter stops
at zero, the output OUT0 / OUT1 remains on the HIGH level.
Terminal assignment
CLK signal
DIR signal
RES signal
OUT signal