5 setting of baud rate and node address (node id), Setting of baud rate and node address (node id), Network via canopen – Lenze EPM−T9XX Modular system User Manual
Page 237

Setting of baud rate and node address (node ID)
Network via CANopen
9.5
L
9.5−1
EDSPM−TXXX−9.0−11/2009
9.5
Setting of baud rate and node address (node ID)
Baud rate
For establishing communication, all devices must use the same baud rate for the
data transfer.
l
The baud rate can be set via the coding switch at the module.
Node address
Each node of the network must be assigned to a node address, also called Node ID
within a range of 1 ... 63 for clear identification.
l
A node address in a network may be used only once.
l
The node address must be set with the coding switch at the module.
0 1
+ +
– –
epm−t024
Fig. 9.5−1
Coding switch at CAN gateway
–
Decrease numerical value
+
Increase numerical value
CANopen
Baud rate
Coding switch value
[kbit/s]
80
1000
81
500
82
250
83
125
84
100
85
50
86
20
87
10
88
800
1. Switch off the voltage supply of the module.
2. Use the coding switch to set the required baud rate.
– Select ’8x’ (x = value of required baud rate)
3. Switch on the voltage supply of the module.
– The LEDs ER, RD and BA are blinking with a frequency of 1 Hz.
4. LEDs ER and BA go off after 5 seconds, and the set baud rate is stored.
Baud rate setting