Page 203: Monitoring digital output monitoring

Monitoring
Digital output monitoring
Networking via system bus (CAN)
8.9
8.9.3
L
8.9−3
EDSPM−TXXX−9.0−11/2009
8.9.3
Monitoring of the analog outputs
Via the index I6443
h
you can configure the reactions of the analog outputs which
are to take place when no telegrams, "node guarding events" or "heartbeat" have
been received in the adjusted monitoring time.
l
Monitoring is started on receipt of the next PDO telegram after the settings.
l
If a telegram is not transmitted within the adjusted time, the module
switches to the "Pre−Operational" state. No further process data are
transmitted.
l
A change into the "Operational" state triggers a reset.
Index
Name
Possible settings
Important
Lenze
Selection
I6443
h
¿
Error mode analog
output
0
{1}
255 Configures analog output monitoring
Index is only available in the modular
system
^ 8.9−3
0
All analog outputs retain the last value output
255
Response from I6444
h
In I6444
h
the response can be configured
individually for each analog output
1 Channel 1
0
2 Channel 2
0
... ...
...
36 Channel 36
0
Via index I6444
h
the response can be configured individually for each analog
output.
Index
Name
Possible settings
Important
Lenze
Selection
I6444
h
¿
Error value analog
output
−32768
{1}
32767 Configures the individual analog output
responses
The analog outputs provide the set value
Index is only available in the modular
system
^ 8.9−3
1 Channel 1
0
2 Channel 2
0
... ...
...
36 Channel 36
0
Individual response setting