2 identifier of the process data objects (pdo), Identifier of the process data objects (pdo), Networking via system bus (can) – Lenze EPM−T9XX Modular system User Manual
Page 176

Transmitting process data
Identifier of the process data objects (PDO)
Networking via system bus (CAN)
8.3
8.3.2
L
8.3−2
EDSPM−TXXX−9.0−11/2009
8.3.2
Identifier of the process data objects (PDO)
The identifiers of process data objects PDO1 ... PDO10 consist of the so−called
basic identifiers and the set node address:
Identifier = Basic identifier + node address
Basic identifier
Available for
dec
hex
CAN gateway
8×dig. I/O compact
16×dig. I/O compact
32×dig. I/O compact
PDOs
Process data object 1
ь
ь
PDO1−Rx
768
300
PDO1−Tx
767
2FF
Process data object 2
ü
—
PDO2−Rx
640
280
PDO2−Tx
639
27F
Process data object 3
ü
—
PDO3−Rx
512
200
PDO3−Tx
384
180
Process data object 4
ü
—
PDO4−Rx
832
340
PDO4−Tx
896
380
Process data object 5
ü
—
PDO5−Rx
1024
400
PDO5−Tx
448
1C0
Process data object 6
ü
—
PDO6−Rx
1088
440
PDO6−Tx
704
2C0
Process data object 7
ü
—
PDO7−Rx
1152
480
PDO7−Tx
960
3C0
Process data object 8
ü
—
PDO8−Rx
1280
500
PDO8−Tx
1216
4C0
Process data object 9
ü
—
PDO9−Rx
1344
540
PDO9−Tx
1728
6C0
Process data object 10
ü
—
PDO10−Rx
1664
680
PDO10−Tx
1984
7C0
Basic identifiers of the process
data objects