B. Supplementary information
B-74
Festo P.BE-MTR-DCI-PB-EN en 1209a
Version FCT PlugIn Min.
CI access
2067h
00h
Var
V-string
r
Description
Minimum version of the MTR-DCI FCT plugin required for commissioning the
MTR-DCI. Format = “xx.yy” (xx = main version, yy = secondary version).
Version FCT PlugIn Opt.
CI access
2068h
00h
Var
V-string
r
Description
Optimum version of the MTR-DCI FCT plugin for commissioning the MTR-DCI.
Format = “xx.yy” (xx = main version, yy = secondary version).
Scaling (control panel settings)
CI access
20D0h
01h, 02h
Array
uint8
rw/r
Description
Definition of the units of measurement used on the control panel and the num-
ber of decimal places. See also CI object 20FFh/PNU 126.
Measuring Unit 20D0h
01h
uint8
rw
Defines the unit of measurement (
Z 20FF03h).
The setting for the system of measurement units only affects the display
readout. All parameters are always saved in increments in the controller and
are not converted into the relevant measuring system until they are written or
read.
Values:
1 (0x01): Metric units of measurement:
e. g. mm, mm/s, mm/s
2
4 (0x04): Angular units of measurement (360°), e.g. degrees, degrees/s, de-
grees/s
2
8 (0x08): Revolutions: rev, rev/min, rev/min
2
15 (0x0F): Increments
Scaling Size 20D0h
02h
uint8
r
Number of places after the decimal point. Fixed: 2. (
Z 20FF04h).