Homing (requires status 1.4 or 1.5), Commissioning 5-55, Step/ description control bytes status bytes – Festo Электромотор MTR-DCI User Manual
Page 143
5. Commissioning
5-55
Festo P.BE-MTR-DCI-PB-EN en 1209a
4. Homing (requires status 1.4 or 1.5)
Step/
Description
Control bytes
Status bytes
Byte
B7
B6
B5 B4
B3 B2 B1
B0
Byte
B7 B6 B5 B4 B3 B2 B1 B0
4.1 Start homing
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON 0
x
x
x
0
x
1
1
SCON 0
x
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS x
0
0
0
0
F
0
1
SPOS 0
0
0
0
0
0
1
1
4.2 Homing is in
progress
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON 0
x
x
x
0
x
1
1
SCON 0
x
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS x
0
0
0
0
1
0
1
SPOS 0
0
0
1
0
0
1
1
4.3 Homing con-
cluded
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON 0
x
x
x
0
x
1
1
SCON 0
x
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS x
0
0
0
0
0
0
1
SPOS
1
0
0
0
0
1
0
1
0: 0-signal;
1: 1-signal;
x: not relevant (any);
F: Edge positive
Tab. 5/12: Control and status bytes for “Homing”
Description for 4. Homing:
4.1
A positive edge at CPOS.B2 (HOM, Start reference
travel) starts the reference travel. The start is confirmed
with SPOS.B1 (acknowledge start) as long as CPOS.B2
(HOM) is set.
4.2
Movement of the axis is shown with SPOS.B4 (MOV,
Axis is moving).
4.3
After successful homing, SPOS.B2 (MC, Motion Com-
plete) and SPOS.B7 (REF) are set.
If there are faults during homing:
} Fault handling: see example 3, Tab. 5/11.