6. Diagnostics and fault display
6-13
Festo P.BE-MTR-DCI-PB-EN en 1209a
The faults are divided into logical groups according to the
fault numbers.
Group
Name
Comment
0
–
No fault active
1 ... 19
Execution fault
Examples: no homing, nominal position outside software end
positions, nominal value calculation not possible.
Although the system is OK, a user command cannot be ex-
ecuted. In most cases there is a fault in operation.
Source: sequence control, controller
20..29
Parameter fault
Example: software end positions outside the effective stroke.
A parameter lies within the limit values, allowing it to be writ-
ten by the user. During the recalculation by the controller,
it was found to be invalid in the context of the other paramet-
ers.
Note: invalid parameters are rejected by the parameter pro-
tocol and do not generate a fault in the controller.
30..49
Controller
Examples: positioning timeout, homing not successful, posi-
tion lag error too large, ...
The task could not be executed correctly. No hardware fault
could be detected. Source: controller
50..69
Initialisation
Fault when initialising the controller
70..79
Controller runtime
Controller runtime fault: undervoltage, checksum
80 ... 89
–
Reserved
90 ... 99
–
Reserved
100 ... 109
Motor runtime
Motor runtime: undervoltage, overtemperature, ...
110 ... 119
–
Reserved
Tab. 6/11: Overview of fault numbers
A detailed description of the warnings and faults can be
found in section 6.3.2.