System show cluster – Allied Telesis AT-S97 User Manual
Page 88
Chapter 5: Port and Module Commands
88
SYSTEM SHOW CLUSTER
Syntax
system show cluster
Parameters
None.
Privilege Levels
Administrator, read-write and read-only.
Description
This command displays the model names and slot assignments of the
management and media converter modules in a chassis or stack, as well
as the chassis’ module name and MAC address. This command does not
display power supply or fan modules.
This command is similar to the SYSTEM SHOW CHASSIS command in
that both commands display the same information about a chassis. Where
they differ is that the SYSTEM SHOW COMMAND can display only one
chassis at a time and requires a chassis ID number. In contrast, this
command displays all of the chassis of a stack and does not require an ID
number.
The SYSTEM SHOW CLUSTER command is typically used to view the
basic information above on a single chassis that is not part of a stack or for
all of the chassis of a stack. The SYSTEM SHOW CHASSIS command is
more intended for situations where there is a stack and, rather than
viewing all of the devices, you want to focus on just one of the units.
Figure 9 on page 89 illustrates this command on a stack of three chassis.
For an explanation of the information, refer to “SYSTEM SHOW
CHASSIS” on page 86.