beautypg.com

System set port – Allied Telesis AT-S97 User Manual

Page 80

background image

Chapter 5: Port and Module Commands

80

SYSTEM SET PORT

Syntax

system set port id=

chassis

/

slot

/[

channel

/]

port

port-state=disable|enable auto-neg=disable|enable
speed=10|100|1000 duplex=half|full
crossover=mdi|mdix
ingress-rate-limit=none|128k|256k|512k|1m|2M|4M|8M
egress-rate-limit=none|128k|256k|512k|1m|2M|4M|8M

Parameters

id

Specifies a twisted pair or fiber optic port on a media

converter module. You can configure only one port at a
time or all the ports of the same type (i.e., twisted pair or
fiber optic ports) on a module. The ID consists of the
following parts:

chassis

Specifies the ID number of a chassis. In version
1.3.0 the ID number of a chassis is 0 or 31.

slot

Specifies the slot number of the media converter
module with the port. Possible values are:

1 or 2

Specifies a slot number of a media
converter slot. In the AT-MCF2000
Chassis, the left slot is 1 and the
right slot is 2.

m

Specifies the 10/100/100Base-T port
on the management module.

channel

Specifies the number of the channel on the
AT-MCF2012LC and AT-MCF2012LC/1
Modules with the port to be configured. To
configure all the ports of the same type, either
twisted pair or fiber optic ports, omit this
parameter. Possible values are:

1 to 12

Specifies a channel. Channel 1
consists of twisted pair port 1 and
fiber topic port 1, channel 2 of twisted
pair port 2 and fiber topic port 2, and
so on. You can specify only one
channel.