Diagnostics show chassis, Figure 38: diagnostics show chassis eeprom command – Allied Telesis AT-S97 User Manual
Page 197
AT-S85 and AT-S97 Management Software Command Line Interface User’s Guide
197
DIAGNOSTICS SHOW CHASSIS
Syntax
diagnostics show chassis id=
chassis
eeprom|software
Parameters
id
Identifies the ID number of a chassis. In version 1.3.0 the
chassis ID number is 0 or 31. To view a unit’s ID number,
use the SYSTEM SHOW CLUSTER command. For
instructions, refer to “SYSTEM SHOW CLUSTER” on
page 88.
eeprom
Displays the serial numbers, hardware revision levels, and
MAC addresses of the modules.
software
Displays the version numbers of the AT-S85 and AT-S97
Management Software on the modules.
Privilege Levels
Administrator, read-write, and read-only.
Description
This command displays manufacturing information about the modules in
the chassis. You might need to provide this information should you contact
Allied Telesis Technical Support for assistance. Figure 38 is an example of
the information supplied by the EEPROM parameter.
Figure 38. DIAGNOSTICS SHOW CHASSIS EEPROM Command
Slot
Module
Module
Serial
HW
MAC
ID
Name
Type
Number
Rev
Address
----------------------------------------------------------------------
C
AT-MCF2000
4
1
00:15:77:70:7A:2A
M
AT-MCF2000M
8
1
00:15:77:70:7A:2B
1
AT-MCF2012LC
20
1
00:15:77:70:7A:2F
2
AT-MCF2012LC
14
1
00:15:77:70:7A:22