beautypg.com

System show chassis, Figure 8: system show chassis command – Allied Telesis AT-S97 User Manual

Page 86

background image

Chapter 5: Port and Module Commands

86

SYSTEM SHOW CHASSIS

Syntax

system show chassis id=

chassis

Parameters

id

Identifies the ID number of a chassis. You can specify only
one chassis at a time. In version 1.3.0, the chassis ID
number is 0 or 31. To view a unit’s ID number, use the
SYSTEM SHOW CLUSTER command. For instructions,
refer to “SYSTEM SHOW CLUSTER” on page 88.

Privilege Levels

Administrator, read-write and read-only.

Description

This command displays the model names and slot assignments of the
management and media converter modules in a chassis, as well as the
chassis’ module name and MAC address. This command does not display
power supply or fan modules.

This command can display just one chassis at a time. To view all of the
chassis of a stack with one command, use the SYSTEM SHOW
CLUSTER command, as explained in “SYSTEM SHOW CLUSTER” on
page 88.

An example of the information is shown in Figure 8.

Figure 8. SYSTEM SHOW CHASSIS Command

Chassis

Chassis

Chassis

MAC

Master

ID

Name

Type

Address

Chassis

------------------------------------------------------------------

0

AT-MCF2000

11:22:33:44:55:55

Yes

Slot ID

Module Name

Module Type

Software Version

------------------------------------------------------------

M

AT-MCF2000M

v1.3.0

1

AT-MCF2012LC

v1.3.0

2

AT-MCF2012LC

v1.3.0

This manual is related to the following products: