System show chassis, Figure 8: system show chassis command – Allied Telesis AT-S97 User Manual
Page 86
Chapter 5: Port and Module Commands
86
SYSTEM SHOW CHASSIS
Syntax
system show chassis id=
chassis
Parameters
id
Identifies the ID number of a chassis. You can specify only
one chassis at a time. In version 1.3.0, the chassis ID
number is 0 or 31. To view a unit’s ID number, use the
SYSTEM SHOW CLUSTER command. For instructions,
refer to “SYSTEM SHOW CLUSTER” on page 88.
Privilege Levels
Administrator, read-write and read-only.
Description
This command displays the model names and slot assignments of the
management and media converter modules in a chassis, as well as the
chassis’ module name and MAC address. This command does not display
power supply or fan modules.
This command can display just one chassis at a time. To view all of the
chassis of a stack with one command, use the SYSTEM SHOW
CLUSTER command, as explained in “SYSTEM SHOW CLUSTER” on
page 88.
An example of the information is shown in Figure 8.
Figure 8. SYSTEM SHOW CHASSIS Command
Chassis
Chassis
Chassis
MAC
Master
ID
Name
Type
Address
Chassis
------------------------------------------------------------------
0
AT-MCF2000
11:22:33:44:55:55
Yes
Slot ID
Module Name
Module Type
Software Version
------------------------------------------------------------
M
AT-MCF2000M
v1.3.0
1
AT-MCF2012LC
v1.3.0
2
AT-MCF2012LC
v1.3.0